The Corrosion and protection Laboratory has a specialty on the teaching and research in the areas of
1) Corrosion & protection of ferrous and non-ferrous metals including stainless steels, super alloys & Ti alloys
2) Alloy Design and Development of high corrosion resistant and bio-materials
3) Corrosion Control of some materials of energy system including power plants and chemical plants
4) Corrosion in Electronics including packagings
The Corrosion and protection Laboratory has many instruments to evaluate corrosion properties and others ;
Potentiostats : EG&G(Model 273A), AC impedance system, Autoclave, Optical Microscope, Mobile Videoscope ,
High Speed cutter(Struers Unitom-2) , Band Saw(KDBS 200), Low Speed cutter(Struers Minitom) , Electric Furnace(Air, Vacuum and Gas condition),
Vacuum Drying Oven(Precision), Constant Temp & Humidity Chamber, Polisher(Struers Rotopol-25), Vibator Polisher(V?P-1003), Auto Polisher
(Struers LaboPol-5), Electric Polisher(Struers LectroPol-5), Rockwell Hardness, Gamry(Model DC 105), Electrochemical Impedance measurement :
Gamry(Model EIS 300), Chemical Corrosion Resistance [CPT, CCT, Corrosion Rate] Tester, Stress Corrosion Cracking(SCC) Resistance Measurements :
SCC test on High Temperatur and High Pressure(Auto Clave), CERT, Tensile Tester, Mini-Barrel Electroplating Unit, Hull Cell Electroplating Unit, Electroless
Plating Unit, Electronic Balanc (open-type, close-type), Electromagnetic Stirrer/Hot Plate, Ultrasonic cleaner, Spot Welder, soldering, pH Meter,
Conductivity & Salinity Meter, Corrosion monitoring system, Spray Tester, Water Purification System, Power Supply & Power Source Meter,
Thermo-Controller, Deep Drawing Unit, Glove box , Drykeeper, Fume Hood, Multimeter